Type |
|
3-Way pressure reducing valve |
|
|
Design |
|
3-way pressure reducing seat valve, pilot operated |
|
|
Mounting method |
|
As requested, preferably vertical |
|
|
Max operating pressure |
|
315 bar in P, A, B 70 bar in T |
|
|
Max flow rate |
|
30 l/min |
|
|
Flow direction |
|
P → A / A → T |
|
|
Hydraulic fluid |
|
Hydraulic oils to DIN 51 524 (1, 2) |
|
|
Hydraulic fluid temperature range |
|
−20 °C ... + 70 °C |
|
|
Viscosity range |
|
15...350 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
Class 16/13 to ISO 4406; 7 to NAS 1638 |
|
|
For mer informasjon |
|
Datablad --- Oversikt |
|
|