Type |
|
Pressure−Reducing Cartridge, Size 10 mm |
|
|
Designation |
|
Pressure−reducing cartridge with two electrically selected pressures |
|
|
Design |
|
Two-stage, seated pilot, spool type main stage, with external pilot drain, solenoid controlled |
|
|
Mounting method |
|
Screw−in cartridge M24 x 1,5 |
|
|
Size |
|
10 mm nominal size, BUCHER cavity type DD |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
315 bar in A and B |
|
|
Max flow rate |
|
120 l/min |
|
|
Flow direction |
|
B → A (see symbols) |
|
|
Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−20 °C ... + 60 °C |
|
|
Viscosity range |
|
10...500 mm²/s (cSt), reommended 15...250 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/14 to ISO 4406 /CETOP RP70H 8 ... 9 to NAS 1638 |
|
|
For mer informasjon |
|
Klikk her --- Oversikt |
|
|