Type |
|
3−Way Priority Flow Control, Size 10 mm |
|
|
Designation |
|
3−way priority flow control valve |
|
|
Design |
|
Spool |
|
|
Mounting method |
|
Screw−in cartridge |
|
|
Size |
|
Nominal size 10 mm, HTF cavity MDD |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
315 bar in A, B and Z |
|
|
Max flow rate |
|
QA: 60 l/min QZ: 19 l/min |
|
|
Flow direction |
|
A = Inlet (supply flow) B = Outlet (surplus flow) Z = Controlled priority flow |
|
|
Hydraulic fluid |
|
HL and HLP mineral oil to DIN 51 524, for other fluids contact HTF |
|
|
Hydraulic fluid temperature range |
|
- 20°C ... + 60 °C |
|
|
Viscosity range |
|
10...300 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/14 to ISO 4406 / CETOP RP70H, 8...9 to NAS 1638 |
|
|
For mer informasjon |
|
Datablad --- Oversikt |
|
|