Type |
|
Inverse Proportional 3−Way Pressure−Reducing Cartridge, Size 2...4 |
|
|
Designation |
|
Inverse proportional 3−way pressure−reducing cartridge |
|
|
Design |
|
Direct acting, electrically operated |
|
|
Mounting method |
|
Push−in cartridge, 4 mounting bolts M4x65 |
|
|
Size |
|
Nominal size 2...4, cavity type AG |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
50 bar, pressure range "04" - Standard model 40 bar, pressure range "03" - Standard model 30 bar, pressure range "02" - Standard model 100 bar, all pressure ranges - Model "H" |
|
|
Max flow rate |
|
12 l/min |
|
|
Flow direction |
|
See symbols |
|
|
Hydraulic fluid |
|
Mineral oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 70 °C |
|
|
Viscosity range |
|
15...380 mm²/s (cSt), recommended 20...130 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/16/13 to ISO 4406 : 1999 |
|
|
For mer informasjon |
|
Klikk her --- Oversikt |
|
|