Type |
|
Proportional 3−Way Pressure−Reducing Cartridge, Size 4 |
|
|
Designation |
|
Proportional 3−way pressure−reducing cartridge |
|
|
Design |
|
Direct acting, electrically operated |
|
|
Mounting method |
|
Push−in cartridge, 4 mounting bolts M4x50 |
|
|
Size |
|
Nominal size 4, cavity type AGS |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
160 bar, pressure range "110" - Standard model 120 bar, pressure range "080" - Standard model 210 bar, both pressure ranges- - Model "H" |
|
|
Max flow rate |
|
10 l/min |
|
|
Flow direction |
|
See symbols |
|
|
Hydraulic fluid |
|
Mineral oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 70 °C |
|
|
Viscosity range |
|
15...380 mm²/s (cSt), recommended 20...130 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/16/13 to ISO 4406 : 1999 |
|
|
For mer informasjon |
|
Datablad --- Oversikt |
|
|